LED Flood Lights

  • Die Cast: Aluminium
  • LED Type : COB
  • Ambient Temp:- 15 C to 65 C
  • Humidity : 0 to 95 % RH
  • Specially Designed fins: max heat dissipation.
  • Efficiency: < 90 % High CRI > 80%.
  • Available in 3000, 4000, 5000, & 6000 k versions.
  • Extra-long life of 50,000 Hrs.
  • Over voltage protection.
  • Lumen Efficiency: 95-120 Lm /w.
  • Ingress Protection–IP: 65 IP 66.
  • Toughened Glass.
  • Over Voltage Protection.
  • Short Circuit Protection.

LED TubeLight with Sensor

  • Supply voltage : 220-240 V ac
  • Operation Voltage : 90-285 V ac
  • Total Lumens : 1900 Lumens
  • Input Wattage : 20w + – 5%
  • Color Temp -2500-6500K
  • Power Factor := > .97
  • Driver : Isolated- Dimmable
  • PCB : Metal Clad
  • Color Rendering Index :> 80%
  • Life (hr) : 50,000
  • Op Temp :-10 to + 55deg C.
  • Sensor Type – Movement Sensor.
  • Range of Sensor -3 meters.
  • Time Setting : One Minute.
  • Power Consumption and Dim Level : 6 W

LED High Bay

  • Al, Al-Cu Clad, Liquid or Active Cooling*
  • Narrow, Medium or Wide Beam
  • Color Temp: 3000 ,4000,5000, & 6000 K
  • Watt – 50, 80, 100, 120, 150, 180, 200 or 250
  • Lens + Reflector + Sec. Reflector*
  • Efficiency: > 90%
  • Life – L90: 40,000 hours
  • Mains Voltage 220 to 240 V / 50-60 hz
  • Installation: Eyebolt Or hanging Brackets
  • Connection: 3 Pole Push-in

LED Street Lights

  • Die Cast Aluminium.
  • Color Temp : 3000,4000,5000,& 6000K
  • Watt – 50,80,100,120,150,180,200 & 250 Watts
  • Light Source: COB – Bridgelux Lumileds, Epistar, Sharp.
  • Efficiency: > 90%
  • Life Time – L90: 40,000 hours
  • Mains Voltage: 220 to 240 V /50-60 Hz
  • Operating Ambient temp -25 C to 70 C

Fuse Gear Switches

  • Double break with side handle operation
  • Positive indication of contacts
  • Suitable for surface mounting
  • Door interlock facility
  • Sheet steel enclosure
  • Side handle operation
  • Suitable for surface mounting
  • Provision of conduit knockouts
  • detachable gland plates

Ranges :

  • 32 Amps/415v
  • 63 Amps/415v
  • 100 Amps/415v
  • 200 Amps/415v

Miniature Circuit Breaker

Range

  • 6.0 A to 40 A – “B” Curve
  • 0.5 A to 63 A – “C” Curve
  • 0.5 A to 63 A – “D” Curve
  • 0.5 A to 63 A for Dc Application

Execution

  • 1P / 1P+N / 2P / 3P / 3P + N /4P

Specification

  • IS / IEC 60898 – 1

Features

  • Low power consumption
  • 15 Plates Arc Chute for effective arc quenching
  • Trip free mechanism

Kit Kat Bar unit

  • 63 Amps / 415v fuse unit
  • 100 Amps / 415v fuse unit
  • 200 Amps / 415v fuse unit
  • 500 Amps / 415v fuse unit

MCB plastic enclosure

Range

  • SP,
  • DP
  • TP
  • FP

Features

  • Suitable surface mounting
  • Knockouts at incoming & outgoing sides
  • Come with dinbars for independent mounting of circuit breakers